Analizator | Sensor zastępczy (zamiennik) – czujnik | |
PSR-12-223 Range Min: 0-10 ppm Oxygen Range Max: 0-1% Oxygen * Signal Output: 295-625 mA Response 90%: 7 sec Expected Life: 18-24 months ** Warranty: 12 months T * Air calibrate on 0-25% range ** Normal applications | Teledyne 3000TA Teledyne 3000TA-XL Teledyne 3010TA Teledyne 3020T Teledyne 3000TB Teledyne 3010TB Teledyne 3160 Teledyne 3190 Teledyne 300T Teledyne 310 Teledyne 311 Teledyne 311D Teledyne 311XL Teledyne 315 Teledyne 316A Teledyne 316B Teledyne 316RA Teledyne 316RB Teledyne 316RBN Teledyne 317RA Teledyne 317RB Teledyne 318 Teledyne 318R Teledyne Insta Trans Teledyne OT-3 Teledyne Turbo 2 Teledyne Tirbo 2P | Teledyne B-2 Teledyne B-2C Teledyne B-2C-AP Teledyne B-2C-XL Teledyne L-2 Teledyne L-2C Teledyne M-2 Teledyne S-2 Teledyne Z-2 Teledyne Insta Trace GE Panametrics OX-1 |
XLT-12-123 *** Range Min: 0-10 ppm Oxygen Range Max: 0-1% Oxygen * Signal Output: 295-625 mA Response 90%: 7 sec Expected Life: 18-24 months ** Warranty: 12 months * Air calibrate on 0-25% range ** Normal applications *** Required CO2 > 0.5% | Refer to PSR-12-223 | Teledyne A-2 Teledyne A-2C GE Panametrics OX-2 |
PSR-11-21 Range: 0-100% Oxygen Signal Output: 295-625 mA Response 90%: 7 sec Life: 12 months Warranty: 9 months | Teledyne 3000PA Teledyne 3000PB Teledyne 3010PA Teledyne 3010PB Teledyne 3020P Teledyne 300P Teledyne 311PC Teledyne 320A Teledyne 320B Teledyne 320BR Teledyne 320BRC Teledyne 320BRCD Teledyne 320C Teledyne 320P Teledyne 320PD Teledyne 326A Teledyne 326B Teledyne 326RA Teledyne 326RB Teledyne 326RBN Teledyne 327RA Teledyne 327RB Teledyne 328 Teledyne 328R Teledyne Insta Trans | Teledyne B-1 |
PSR-11-213 Range: 0-100% Oxygen Signal Output: 295-625 mA Response 90%: 7 sec Expected Life: 12 months Warranty: 9 months | Refer to PSR-11-23 | Teledyne B-1C Scottish Anglo /Analox B1SA |
PSR-11-23 Range: 0-100% Oxygen Signal Output: 235-355 mA Response 90%: 13 sec Expected Life: 15 months Warranty: 12 months | Tak jak PSR-11-21 Teledyne 335 Teledyne 3350 | Teledyne B-3 GE Panametrics OX-3 |
PSR-11-233 Range: 0-100% Oxygen Signal Output: 235-355 mA Response 90%: 13 sec Expected Life: 15 months Warranty: 12 months | ||
PSR-11-330 Range: 0-100% Oxygen Signal Output: 165-235 mA Response 90%: 30 sec Expected Life: 24 months Warranty: 12 months | Teledyne C-3 Scottish Anglo C3SA | |
PSR-11-33-B Range: 0-100% Oxygen Signal Output: 165-235 mA Response 90%: 30 sec Expected Life: 24 months Warranty: 12 months | Bacharach | Bacharach |
PSR-11-54 Range: 0-100% Oxygen Signal Output: 165-235 mA Response 90%: 7 sec Expected Life: 24 months Warranty: 12 months | Refer to PSR-11-33 proprietary AII option | Teledyne C-3 Scottish Anglo C3SA |
XLT-11-15 * Range: 0-100% Oxygen Signal Output: 165-235 mA Response 90%: 30 sec Expected Life: 15 months * Warranty: 12 months | * Required CO2 > 0.5% | Teledyne A-3, A-5 GE Panametrics OX-4 |
PSR-11-52 Range: 0-100% Oxygen Signal Output: -40 to -80 mA Response 90%: 7 sec Expected Life: 60 months Warranty: 24 months | Teledyne 3300 Teledyne 3290 Teledyne 329 | Teledyne E-2 |
PSR-11-39 Range: 0-100% Oxygen Signal Output: 7-13 mV Response 90%: 6 sec Expected Life: 36 months Warranty: 12 months | California Analytical MSA Teledyne | California Analytical MSA 466324 Teledyne R-22 |
XLT-11-39-1 Range: 0-100% Oxygen Signal Output: 7-13 mV Response 90%: 6 sec Expected Life: 12 months Warranty: 8 months | California Analytical | California Analytical |
PSR-11-75-KE Range: 0-100% Oxygen Signal Output: 10-14 mV Response 90%: 13 sec Expected Life: 60 months Warranty: 24 months | Various | Figaro (Japan Storage Battery) KE-25 Sierra Instruments |
PSR-11-75-KE4 Range: 0-100% Oxygen Signal Output: 10-14 mV Response 90%: 13 sec Expected Life: 60 months Warranty: 18 months | Rosemount | Figaro (Japan Storage Battery) KE-25F4 |
PSR-11-77 Range: 0-100% Oxygen Signal Output: 7-13 mV Response 90%: 6 sec Expected Life: 60 months Warranty: 18 months | Teledyne 60 Teledyne 190 Teledyne 200 | Teledyne T-7 (A51327) |
GPR-11-917-J Range: 0-100% Oxygen Signal Output: 7-13 mV Response 90%: 6 sec Expected Life: 36 months Warranty: 12 months | Automotive Exhaust | City Tech Envitech MSA Teledyne R-17A |
GPR-11-917-M Range: 0-100% Oxygen Signal Output: 7-13 mV Response 90%: 6 sec Expected Life: 36 months Warranty: 12 months | Automotive Exhaust | City Tech Envitech MSA Teledyne R-22A |